Getting Started
Part No.: 4417584_Rev12 Configuration Manual
CIU 888 3 - 39
You can view or edit these properties:
9. Click the Floating Roof tab, the Properties detail appears.
You can view or edit these properties:
Properties Description
Tank capacity table The file name and path of the TCT file selected by the
user.
This entity is stored in the site database but will not be
downloaded to any CIU.
Level type Tank type
This is a bit coded entity which contains the following
information:
Bit 0 = 1 Level measurement is Ullage if bit is set : the
Level value decreases when product is pumped into the
tank, level 0 is at or near the top of the tank [Innage (0):
lev
Properties Description
Zone enabled:
Zone 1 Enabled Check to enable the option.
Zone 2 Enabled Check to enable the option.
No GOV calculation:
Zone 1 No GOV calcula-
tion
Check to disable volume calculation when level is in
zone 1.
Zone 2 No GOV calcula-
tion
Check to disable volume calculation when level is in
zone 2.
No Water Volume calculation:
Zone 1 No Water
Volume calculation
Check to disable the option.
Zone 2 No Water
Volume calculation
Check to disable the option.
Roof Weight: