Honeywell CUL6438SR-CV1 Specifications

General IconGeneral
BrandHoneywell
ModelCUL6438SR-CV1
CategoryController
LanguageEnglish

Summary

INTRODUCTION

Description of Devices

Overview of Stryker™ Lon Configurable CVAHU Controller and Zio/Zio Plus LCD Wall Modules.

Stryker CVAHU Controller Features

Details on the CUL6438SR-CV1 controller, its features, and compatibility with Niagara Framework.

Zio Wall Module Features

Key features of the Stryker™ Lon Configurable CVAHU Controller, including network protocol and configuration.

Zio/Zio Plus LCD Wall Modules

General Description

Description of TR70 and TR75 series Zio/Zio Plus LCD wall modules and their capabilities.

Wall Module Features

Key features of the TR70 Series wall modules, including tenant access and parameter customization.

Control Application Overview

How Stryker CVAHU systems use Zio wall modules for commercial building HVAC control.

Control Provided

CVAHU Controller Functions

Details on how the CVAHU controller manages heating, cooling, economizers, and system fan operations.

Heat Pump Control

How the CVAHU controller manages heat pump units, compressors, and auxiliary heat.

Products Covered

Covered Products List

List of products covered, including controller, wall modules, and termination module.

Manual Organization

Overview of the manual's structure, divided into introduction and configuration sections.

Applicable Literature

List of related documents for Stryker CVAHU and Zio wall modules, including specification data and installation guides.

Product Naming

Names of Stryker CVAHU controllers and TR70/TR75 Zio wall module models.

Agency Listings

Agency Certification Details

Details on agency certifications and compliance for Stryker CVAHU controller and Zio wall modules.

Abbreviations

Technical Terminology

Glossary of technical terms and acronyms used in the manual for CVAHU and Zio systems.

Controller and Wall Module Construction

Construction Reference Literature

References to literature detailing the construction and specifications of controllers and wall modules.

Stryker CVAHU Configuration via Zio Wall Module

Wall Module Compatibility

Information on the compatibility of TR70 Series LCD Wall Modules with Stryker controllers.

Contractor Mode Introduction

Introduction to Contractor Mode for navigating and configuring parameters on the Zio wall module.

Initial Power-Up Procedure

Unsupported Zio Features

List of controller features that are not supported when using Zio configuration.

Default Controller Configuration

Details on the default configuration settings for the CVAHU controller when using Zio.

Contractor Mode Configuration Steps

Setting the Home Screen

Procedure for selecting and setting the default home screen for the tenant view.

Configure View More Options

Tenant View Access Settings

Procedure for providing tenant access to parameters via the View More screen.

Parameters

Sensors Parameter Group

Overview of sensor parameters available for configuration and monitoring in the Zio system.

Status Parameter Group

Overview of status parameters for CVAHU controller, including output signals and limits.

Temp SP Parameter Group

Overview of temperature setpoint configuration parameters for CVAHU.

Override Parameter Group

Overview of override parameters for CVAHU systems.

Alarms Parameter Group

Overview of alarm parameters and status for CVAHU.

Snsr Cal Parameter Group

Overview of sensor calibration parameters for CVAHU.

Wm Config Parameter Group

Overview of wall module configuration parameters.

Cnfg Ctl Parameter Group

Overview of control configuration parameters for CVAHU.

Cnfg Ui Parameter Group

Overview of universal input configuration parameters.

Cnfg Di Parameter Group

Overview of digital input configuration parameters.

Cnfg In Parameter Group

Overview of input configuration parameters for CVAHU.

Analog Output Range Groups

Overview of analog output range configuration parameters (AO1, AO2, AO3).

Cnfg Out Parameter Group

Overview of analog and digital output configuration parameters.

Time and Date Settings Group

Overview of time and date configuration parameters.

Schedule Parameter Group

Overview of schedule configuration parameters.

Sensors

ZIO TEMP Sensor

Display and configuration of Zio temperature sensor readings.

ZIO HUMIDITY Sensor

Display and configuration of Zio humidity sensor readings from the wall module.

ROOMTEMP Sensor

Display and configuration of room temperature readings.

RH Sensor

Display and configuration of room relative humidity readings.

CO2 Sensor

Display and configuration of room CO2 (PPM) readings.

DISCHRG Sensor

Display and configuration of discharge air temperature readings.

OAT Sensor

Display and configuration of outside air temperature readings.

OAH Sensor

Display and configuration of outside air humidity readings.

OCC SNSR Sensor

Display and configuration of occupancy sensor status and modes.

WINDOW Sensor

Display and configuration of window open/closed contact status.

MON SWTH Sensor

Display and configuration of monitoring switch status.

MON MODU Sensor

Display and configuration of monitored modulation status.

Status Parameters

HTG OUT Status

Display of heating output signal status.

CLG OUT Status

Display of cooling output signal status.

DAMPER Status

Display of damper (%) output signal status.

DMD LIMIT Status

Display of demand limit setpoint shift status.

Status Parameters

TRMnl LD Status

Display of effective terminal load (%) on the controller.

Free MOD Status

Display of configured free modulating (%) output signal.

Aux Econ Status

Display of auxiliary economizer status as ON or OFF.

Free Dtg Status

Display of configured free digital 1 command status as ON or OFF.

Status Parameters

FAN Status

Display of fan digital output status as ON or OFF.

Temp Sp (Temperature Setpoint Configuration)

OCC CLG Setpoint

Display and modification of occupied cooling setpoint.

UNOC CLG Setpoint

Display and modification of unoccupied cooling setpoint.

OCC HTG Setpoint

Display and modification of occupied heating setpoint.

UNOC HTG Setpoint

Display and modification of unoccupied heating setpoint.

Temp Sp (Temperature Setpoint Configuration)

STBY CLG Setpoint

Display and modification of standby cooling setpoint.

SETPOINT Display

Display and modification of centre setpoint read from wall module.

STBY HTG Setpoint

Display and modification of standby heating setpoint.

FRZ PRTC Setpoint

Display and modification of Space freeze protection setpoint.

Temp Sp (Temperature Setpoint Configuration)

EFF SP Setpoint

Display of room temperature effective setpoint.

Override Parameters

FAN Override

Display and modification of supply fan override command.

Alarms Parameters

EMRG OVRD Alarm

Display smoke detector status as TRUE, FALS or UNDEFINED.

CLG OVRD Alarm

Display cooling override status as TRUE, FALS or UNDEFINED.

Alarms Parameters

HTG OVRD Alarm

Display heating override status as TRUE, FALS or UNDEFINED.

FROST Alarm

Display frost override status as TRUE, FALS or UNDEFINED.

FAN OVRD Alarm

Display fan override status as TRUE, FALS or UNDEFINED.

IAQ ALM Alarm

Display IAQ alarm override status as TRUE, FALS or UNDEFINED.

Alarms Parameters

INVLD SP Alarm

Display invalid setpoint override status as TRUE, FALS or UNDEFINED.

SPC TEMP Alarm

Display space temperature override status as TRUE, FALS or UNDEFINED.

Snsr Calibration

ZIO T OF Calibration

Display and modification of Zio temperature offset.

ZIO H OF Calibration

Display and modification of Zio humidity (%) offset.

Wm Config (Wall Module Configuration)

UNITS Configuration

Display and modification of units for temperature parameters (C, F).

TYPE Configuration

Display and modification of wall module type (NONE, TR20, ZIO).

Wm Config (Wall Module Configuration)

CNTR SP Configuration

Display and modification of centre setpoint usage (FALS, TRUE).

CNTSP HI Configuration

Display and modification of centre setpoint high limit.

CNTSP LO Configuration

Display and modification of centre setpoint low limit.

BYPS MIN Configuration

Display and modification of wall module bypass time setpoint.

Wm Config (Wall Module Configuration)

HTGSP HI Configuration

Display and modification of heating setpoint high limit.

CLGSP HI Configuration

Display and modification of cooling setpoint high limit.

HTGSP LO Configuration

Display and modification of heating setpoint low limit.

CLGSP LO Configuration

Display and modification of cooling setpoint low limit.

Wm Config (Wall Module Configuration)

EFHTG HI Configuration

Display effective heating high setpoint.

EFCLG HI Configuration

Display effective cooling high setpoint.

EFHTG LO Configuration

Display effective heating low setpoint.

EFCLG LO Configuration

Display effective cooling low setpoint.

Cnfg Ctl (Control Configuration)

HP TYPE Configuration

Display and modification of heat pump type selection (CON, GSHP, ASHP).

CLG TR Configuration

Display and modification of space cooling PID control throttling range.

CLG TYPE Configuration

Display and modification of number of cooling/heat pump stages.

Cnfg Ctl (Control Configuration)

CLG IT Configuration

Display and modification of cooling PID control integral time.

HTG TYPE Configuration

Display and modification of heating output type for auxiliary heat.

Cnfg Ctl (Control Configuration)

HTG TR Configuration

Display and modification of space heating PID control throttling range.

HTG IT Configuration

Display and modification of heating PID control integral time.

Cnfg Ctl (Control Configuration)

FAN MODE Configuration

Display and modification of fan mode for CVAHU.

OC SNRP Configuration

Display and modification of occupancy sensor operation status.

Cnfg Ui (Universal Input Configuration)

UI 1 Configuration

Display and modification of input type for universal input 1.

Cnfg Di (Digital Input Configuration)

DI 1 Configuration

Display and modification of input type for digital input 1.

Cnfg In (Input Configuration)

SPC TEMP Input Config

Display and modification of logical input config for space temperature.

SPC RH Input Config

Display and modification of logical input config for space relative humidity.

Cnfg In (Input Configuration)

SPC CO2 Input Config

Display and modification of logical input config for space CO2.

DISCHAIR Input Config

Display and modification of logical input config for discharge air temperature.

Cnfg In (Input Configuration)

MIXEDAIR Input Config

Display and modification of logical input config for mixed air temperature.

OD TEMP Input Config

Display and modification of logical input config for outside air temperature.

Cnfg In (Input Configuration)

OCC SNSR Input Config

Display and modification of logical input config for occupancy sensor.

WINDOW Input Config

Display and modification of logical input config for window contacts.

AO1 Range Configuration

AO1 Range Settings

Display and modification of analog output 1 range.

AO2 Range Configuration

AO2 Range Settings

Display and modification of analog output 2 range.

AO3 Range Configuration

AO3 Range Settings

Display and modification of analog output 3 range.

Cnfg Out (Output Configuration)

CLG STG1 Output Config

Display and modification of logical output config for Cooling/Heat Pump stage 1.

CLG STG2 Output Config

Display and modification of logical output config for Cooling/Heat Pump stage 2.

Cnfg Out (Output Configuration)

CLG STG3 Output Config

Display and modification of logical output config for Cooling/Heat Pump stage 3.

HP CHANG Output Config

Display and modification of Heat Pump change over relay command.

Cnfg Out (Output Configuration)

HTG STG1 Output Config

Display and modification of logical output config for Heating stage 1.

HTG STG2 Output Config

Display and modification of logical output config for Heating stage 2.

Cnfg Out (Output Configuration)

HTG STG3 Output Config

Display and modification of logical output config for Heating stage 3.

FAN OUT Output Config

Display and modification of logical output config for Fan Start-Stop Command.

Cnfg Out (Output Configuration)

DAMPER Output Config

Display and modification of logical output config for Damper control signal.

Time Display

Current Time Display

Displays current controller time in HH MM format.

Set Time Configuration

Set Time Hours

Display and modification of time in hours.

Set Time Minutes

Display and modification of time in minutes.

Set Date Configuration

Set Date Year

Display and modification of date in years.

Set Date Month

Display and modification of date in months.

Set Date Configuration

Set Date Day

Display and modification of date in days.

Schedule Configuration

Accessing Schedule Parameters

Procedure to access the schedule parameter group.

Editing Monday Schedule

Steps for viewing and editing the schedule for Monday events.

Editing Schedule Events

Procedure for changing time and occupancy state for schedule events.

Tenant Mode Introduction

Tenant Adjustable Features

Features tenants can change, like Setpoints, Fan speed, System mode, and Override.

Tenant Mode Home Screen

Description of the default Tenant mode home screen and its soft key options.

Tenant Mode Fan Settings

AUTO Fan Mode

Description of AUTO fan mode operation.

ON Fan Mode

Description of manual ON fan mode operation.

OFF Fan Mode

Description of manual OFF fan mode operation.

Tenant Mode Override

Override Functionality

How tenants can override occupancy settings for a specified duration.

Canceling Override

Procedure for canceling an active tenant override.

Tenant Mode System & View More

Changing System Mode

How to change system state (Off, Auto, Cool, Heat) and view parameters.

Tenant Parameter Adjustment

How tenants can adjust parameter values if enabled by the contractor.

Tenant Mode Room Temperature

Room Temperature Display

Displays room temperature and its input to the Sbus wall module.

Tenant Mode Humidity

Room Humidity Display

Displays room humidity and its input to the Sbus wall module.

Tenant Mode Outdoor Air Temp

OAT Display

Displays outside air temperature and its input to the Sbus wall module.

Tenant Mode Center Setpoint

CNTR SP Display

Displays and allows modification of centre setpoint.

Tenant Mode Effective Setpoint

EFF SP Display

Displays effective setpoint and its input to the Sbus wall module.

Tenant Mode Time

Controller Time Display

Displays controller time in HH:MM format.

Tenant Mode Time Adjustment

Tenant Mode Hours Adjustment

Allows modification of time in hours.

Tenant Mode Minutes Adjustment

Allows modification of time in minutes.

Tenant Mode Date Adjustment

Tenant Mode Year Adjustment

Allows modification of date in years.