2 - 9
Decode Mirror Images (Data Matrix Only)
Select an option for decoding mirror image Data Matrix bar codes:
Always - decode only Data Matrix bar codes that are mirror images
Never - do not decode Data Matrix bar codes that are mirror images
Auto - decode both mirrored and un-mirrored Data Matrix bar codes.
Decode Session Timeout
This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1
second increments from 0.5 to 9.9 seconds. If a label has not been decoded before this time expires and the session is
terminated, the software regards it as a failed scan attempt. Default = 9.9 Seconds.
To begin setting a decode session time-out in seconds, scan this Decode Session Timeout bar code:
Next, scan two numeric bar codes that correspond to the desired time-out using the Imager Keypad Number Symbols page.
Times less than 1.0 second must have a leading zero.
If you wish to change your number selection, scan Cancel on the Imager Keypad Number Symbols page.
* Never
Always
Auto