Loading...
2 - 58
Codabar
When enabled, Codabar symbols will be scanned, decoded and transmitted.
Set this parameter by scanning either of the bar codes shown below.
CLSI Editing
When enabled, the start and stop characters are stripped from the bar code and a space is inserted after the 1
st
, 5
th
, and
10
th
characters of a 14 character Codabar symbol.
Set this parameter by scanning either of the bar codes shown below.
Note: Symbol length does not include start and stop characters.
Enable Codabar
* Disable Codabar
Enable CLSI Editing
* Disable CLSI Editing