2 - 24
1 Two check digits.
3 Check characters validated but not transmitted.
GS1 DataBar Family
No option specified at this time. Always transmit 0. GS1 DataBar-14 and GS1 DataBar-
Limited transmit with an Application Identifier “01”.
Note: In UCC/EAN-128 emulation mode, GS1 DataBar is transmitted using Code 128 rules
(i.e., ]C1).
Example: An GS1 DataBar-14 bar code 100123456788902 is transmitted as
]e001100123456788902.
EAN/UCC Composites (GS1 DataBar, UCC/EAN-128, 2D portion of UPC composite)
Native mode transmission. Note: UPC portion of composite is transmitted using UPC rules.
0 Standard data packet.
1 Data packet containing the data following an encoded symbol separator character.
2 Data packet containing the data following an escape mechanism character. The data packet
does not support the ECI protocol.
3 Data packet containing the data following an escape mechanism character. The data packet
supports the ECI protocol.
- UCC/EAN-128 emulation
Note: UPC portion of composite is transmitted using UPC rules.
1 Data packet is a UCC/EAN-128 symbol (i.e., data is preceded with ]JC1).
PDF417, Micro PDF417
0 Reader set to conform to protocol defined in 1994 PDF417 symbology specifications. Note:
When this option is transmitted, the receiver cannot reliably determine whether ECIs have
been invoked or whether data byte 92DEC has been doubled in transmission.
1 Reader set to follow the ECI protocol (Extended Channel Interpretation). All data characters
92DEC are doubled.
2 Reader set for Basic Channel operation (no escape character transmission protocol). Data
characters 92DEC are not doubled. Note: When decoders are set to this mode, unbuffered
Macro symbols and symbols requiring the decoder to convey ECI escape sequences cannot
be transmitted.
3 The bar code contains a UCC/EAN-128 symbol, and the first codeword is 903-907, 912,
914, 915.
4 The bar code contains a UCC/EAN-128 symbol, and the first codeword is in the range 908-
909.
5 The bar code contains a UCC/EAN-128 symbol, and the first codeword is in the range 910-
911.
Example: A PDF417 bar code ABCD, with no transmission protocol enabled, is transmitted
as ]L2ABCD.
Data Matrix
0 ECC 000-140, not supported.
1 ECC 200.
2 ECC 200, FNC1 in first or fifth position.
3 ECC 200, FNC1 in second or sixth position.
4 ECC 200, ECI protocol implemented.
5 ECC 200, FNC1 in first or fifth position, ECI protocol implemented.
6 ECC 200, FNC1 in second or sixth position, ECI protocol implemented.
Code
Type
Option
Value
Option