Item
No. Item Name Description
————————————————————————————————————————
028 GAS TEMP HILIM High limit for temperature, initiates alarm ( items 106 and
146) if exceeded. Also used with Item 004.
Default = 165.00
029 REF TEMP #1 The temperature value used during the most recent TZERO
calibration.
Default = 0.00
030 REF TEMP #2 The temperature value used during the most recent TCAL
calibration.
Default = 0.00
031 CASE TEMP Temperature measured inside instrument case at last wake-up.
Default = 0.00
032 CASE TEMP MAX Highest case temperature measured by unit since last manually
reset.
Default = -40.00
033 CASE TEMP MIN Lowest case temperature measured by unit since last manually
reset.
Default = 099999.99
034 BASE TEMP Base temperature per the contract, used to calculate
temperature correction factor (item 045).
Default = 60.00
035 TCAL ZERO The most recent offset value for the temperature transducer,
obtained during a T-Zero calibration. The value is normally
very close to 0.0000 and is recalculated during each
Temperature Zero Calibration.
Default = 0.0000
036 1 PREV TCAL ZERO The previous value of item 035, updated on each Temperature
Zero Calibration.
Default = 0.0000
037 2 PREV TCAL ZERO The previous value of item 036, updated on each Temperature
Zero Calibration.
Default = 0.0000