Mini-AT User Guide
Default = 00000000
Item
No. Item Name Description
————————————————————————————————————————
247 MO PK DAY DATE The date the current month Peak Day CORVOL (245) occurred.
Format: Determined by item 262
Default = 01-01-98
248 PREMO PK HR CRVL The highest hourly CORVOL of the previous ‘Gas’ month.
Default = 00000000
249 PREMO PK HR DATE The date the previous month Peak Hour CORVOL (248) occurred.
Format: Determined by item 262
Default = 01-01-98
250 PREMO PK HR TIME Ending hour for the previous month Peak Hour CORVOL Date
(249).
Default = 00 00 00
251 PREMO PKDAY CRVL The highest Daily CORVOL (item 223) of the previous ‘Gas’
month.
Default = 00000000
252 PREMO PKDAY DATE The date the previous month Peak Day CORVOL (251) occurred.
Format: Determined by item 262
Default = 01-01-98
253 MAX DAY CORVOL The highest Daily CORVOL (item 223) since last manually reset.
Default = 00000000
254 MAX DAY DATE The date the MAX DAY CORVOL (253) occurred.
Format: Determined by item 262
Default = 01-01-98
256 PCOR DAILY AVG PRESS The daily average of PCor Gas Pressure (item 008) which will be
reset to zero at the start of each Gas Day.
Default = 0.00
257 DAILY AVG TEMP The daily average Gas Temperature (026) which will be reset to
zero at the start of each Gas Day.