Item
No. Item Name Description
————————————————————————————————————————
229 OPTN REP ITEM 1 The last six of ten, user selectable Audit Trail Report Items that can
be placed in Audit Trail memory. The use of these six items is
optional. If any of these six items are other than 255, the
instrument is forced to store the maximum of ten audit items per
record. In this case, up to five 255s can be used to specify a blank
(unused) column. To configure audit trail memory for only four
items per record, place a 255 in all six item codes (229 - 234). If
audit trail memory is configured for four items and then is to be
returned back to the default ten item arrangement, the instrument
must betaken UNCONFIGURED by jumpering pins 3 & 4 of
JB24 and cycling the power. This will erase all audit trail data,
and re- map the RAM memory for ten item configuration.
Default: 048 (Battery Voltage)
230 OPTN REP ITEM 2 See above. Default: 000 (CorVol)
231 OPTN REP ITEM 3 See above. Default: 002 (UncVol)
232 OPTN REP ITEM 4 See above. Default: 008 (PCor Gas Pressure)
233 OPTN REP ITEM 5 See above. Default: 026 (Gas Temperature)
234 OPTN REP ITEM 6 See above. Default: 059 (Battery Wake Cycles)
235 REPORT TRIGGER 1 Audit Trail Time Intervals: TIME
236 REPORT TRIGGER 2 Daily Nominated Volume Reached: VOLUME
237 REPORT TRIGGER 3 Alarm Activations: ALARM
238 REPORT TRIGGER 4 Serial Access: SERIAL
239 REPORT TRIGGER 5 Meter Reader (Mag Wand) Access: MAG READ
240 REPORT TRIGGER 6 OBSOLETE
241 REPORT TRIGGER 7 OBSOLETE
242 REPORT TRIGGER 8 Changes to item values: CHANGE