OMNI-408/OMNI-408EU Installation and Setup Guide
7–6
QUESTION 07
KEYPAD CONDITIONS DEFAULT = 1004
This question contains 4 locations (L1-L4).
Question 07, L1
Keypad Panic, Fire and Auxiliary Default = 1
Enter the digit for the desired system options from the table below in Location L1.
NOTE: The checkmarks highlight which options are selected.
KEYPAD AUXILIARY
Digit
KEYPAD
PANIC
KEYPAD
FIRE
KEYPAD
AUXILIARY
AUDIBLE SILENT
0 NONE (K.P. CONDITIONS DISABLED)
1
9
2
9
3
9 9
4
9
9
5
9
9
9
6
9 9
9
7
9 9 9
9
C
9 9
D
9
9 9
E
9 9 9
F
9 9 9 9
NOTE: The Keypad Auxiliary
Audible/Silent selection refers to
keypad sounder only (not the bell).
Keypad Fire is always Audible.
Keypad Panic may be Audible or
Silent, based on the choice made in
Question 06, Location 4.
KEYPAD PANIC - If AUDIBLE, pressing the two Panic keys at the same time (or [#] [*] at the
same time) annunciates the keypad sounder (STEADY SOUND) and turns on the bell output (STEADY
SOUND). If SILENT, it does not annunciate the keypad sounder and turn on the bell output. In both
cases, it transmits a CS code if programmed to do so in Question 20, Locations 1 and 2.
KEYPAD FIRE - If selected, pressing the two Fire keys at the same time (or [7] [9] at the same
time) annunciates the keypad sounder (PULSING SOUND) and turns on the bell output (PULSING
SOUND). It transmits a CS code if programmed to do so in Question 23, Locations 1 and 2.
KEYPAD AUXILIARY - If AUDIBLE, pressing the two Aux. keys at the same time (or [1] [3] at
the same time) ONLY annunciates the keypad sounder (PULSING SOUND). If SILENT, then it does
not annunciate the keypad sounder or turn on the bell output. It transmits a CS code if programmed to
do so in Question 23, Locations 3 and 4.