Section 7 - System Programming
77
NOTE: The checkmarks highlight which options are selected.
DIALING PULSE TYPE
Digit
ARM
FAULTED
US EUROPEAN
AUTO
STAY
0
9
1
9 9
2
9
3
9
9
4
9
9
U
L
European Pulse has not been tested for
UL installations.
5
9 9
9
6
9 9
7
9
9 9
ARM FAULTED - If enabled, this allows the user to arm the system independent of the status of any
delay or interior zones. If the system is armed with any delay or interior zone faulted, an Exit Error
occurs at the end of the exit time unless the faulted zones become restored.
DIALING PULSE TYPE - Specifies how this control will perform pulse dialing (U.S. Pulse or
European Pulse) when CS transmissions are enabled.
AUTO STAY - If enabled, the system will arm Auto Stay, bypassing interior zones programmed as
Stay zones if the Entry Exit zone is not faulted during exit time. If an instant zone or a delay zone is
programmed for Bypass in Stay, the panel will not arm Auto Stay if it is enabled.
Question 07 L3
Quick Commands & Quick Exit Default = 0
Enter the digit from the table below in Location L2.
NOTE: The checkmarks highlight which options are selected.
QUICK COMMANDS
Digit
QUICK FORCED
ARMING
QUICK
ARMING
QUICK
BYPASS
QUICK
EXIT
0 NONE
1
9
2
9
3
9 9
4
9
5
9
9
6
9
9
7
9 9
9
U
L
For UL installations, do not
select Quick Forced Arming.
8
9
9
9
9
A
9 9
B
9 9 9
C
9 9
D
9
9 9
E
9 9 9
F
9 9 9 9