5.1 Wiring Diagrams and Dimension Drawings, Continued
Dimension Drawings
The tables on the following pages list available dimension drawings for
reference. If you need a copy of a drawing, please determine the
appropriate drawing number from the following tables and contact your
Honeywell representative to obtain a copy.
Dimension Drawings - Series 100 and Series 900
Transmitter Type and Table Mounting Drawing
Key Number Selections
Angle Bracket (MB), (SB) Flat Bracket (FB) Number
Vertical
Pipe
Horizontal
Pipe
Vertical
Pipe
Horizontal
Pipe
Differential Pressure
STD110, STD120, STD125*,
See Key Number
51205895 51205893
STD130, STD170
Column
51205894 51205892
*STD125 – Tank HTG 30756435-
000
STD904, STD924, STD930, Table I - 51500357 51500355
STD974 C, D, G, H, K, L 51500356 51500354
STD924, STD930 Table I - X X
A, B, E, F, J X X
Transmitter Type and
Equipped with
Angle Bracket (MB), (SB) Flat Bracket (FB) Drawing
Key Number
A-G manifold
part #
Vertical
Pipe
Horizontal
Pipe
Vertical
Pipe
Horizontal
Pipe
Number
Differential Pressure
(with Anderson-Greenwood 3-way
valve manifold)
STD110, STD120, STD125*, M4AV1 51500426 51500424 51500428 51500422
STD130, STD170 M4TV1 51500427 51500425 51500429 51500423
STD924, STD930 M4AV1 51500431 51500433 51500435 51500437
M4TV1 51500430 51500432 51500434 51500436
STD904, STD924, STD930, M4AV1 51500442 51500440 51500444 51500438
STD974 M4TV1 51500443 51500441 51500445 51500439
Continued on next page
46 ST 3000 Release 300 Installation Guide 2/05

Table of Contents

Other manuals for Honeywell ST 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell ST 3000 and is the answer not in the manual?

Honeywell ST 3000 Specifications

General IconGeneral
ManufacturerHoneywell
CategoryTransmitter
Stability±0.01% of URL per year
Operating Temperature-40 to 85°C (-40 to 185°F)
Communication ProtocolHART
Housing MaterialAluminum or Stainless Steel
Enclosure RatingIP66/67, NEMA 4X
Measurement TypeGauge, Absolute, Differential
Output Signal4-20 mA, HART
Process Temperature-40 to 121°C (-40 to 250°F)
Hazardous Area ApprovalsFM, CSA, ATEX, IECEx
Process Connection1/2" NPT
Material316L Stainless Steel, Hastelloy C