Xenon XP User Guide 115
Multiple Symbols
When this programming selection is turned On, it allows you to read multiple
symbols with a single pull of the scanner’s trigger. If you press and hold the trigger,
aiming the scanner at a series of symbols, it reads unique symbols once, beeping
and or vibrating (if turned on) for each read. The scanner attempts to find and
decode new symbols as long as the trigger is pulled. The maximum number of
barcodes read is 21. When this programming selection is turned Off, the scanner
will only read the symbol closest to the aiming beam. Default = Off.
No Read
With No Read turned On, the scanner notifies you if a code cannot be read. If using
an EZConfig-Scanning Tool Scan Data Window (see page 239), an “NR” appears
when a code cannot be read. If No Read is turned Off, the “NR” will not appear.
Default = Off.
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you
can edit the output message (see Data Format beginning on page 133). The hex
code for the No Read symbol is 9C.
* Error Tone - Partial
Sequence Output
On
* Off
On
* Off