190 Xenon XP User Guide
MSI Check Character
Different types of check characters are used with MSI barcodes. You can program
the scanner to read MSI barcodes with Type 10 check characters. Default = Validate
Type 10, but Don’t Transmit.
When Check Character is set to Validate Type 10/11 and Transmit, the scanner
will only read MSI barcodes printed with the specified type check character(s), and
will transmit the character(s) at the end of the scanned data.
When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit
will only read MSI barcodes printed with the specified type check character(s), but
will not transmit the check character(s) with the scanned data.
* Validate Type 10, but Don’t
Transmit
Validate Type 10 and Transmit
Validate 2 Type 10 Characters,
but Don’t Transmit
Validate 2 Type 10 Characters
and Transmit
Validate Type 11 then Type 10
Character, but Don’t Transmit
Validate Type 11 then
Type 10 Character and Transmit
Disable MSI Check Characters