B-5
i. The power supply auto-ranges to the AC voltage and frequency. It does not have to be reconfigured to operate over its rated
operating ranges.
Table B-10. Electrical Specifications.
Description Specification
HP 9000 -
K100, K200, K400, K210,
K410, K220, & K420
HP 3000 - 939KS, 959KS, 929KS,
969KS/x00, & 969KS/x20
HP 9000 - K250, K260, K450, & K460
HP 3000 - 979KS
AC Input Voltage Range
i
100 to 127 VAC or 200 to 240 VAC 90 to 143 VAC or 180 to 269 VAC
AC Input Line frequency
i
50 to 60 Hz 50 to 60 Hz
AC Input Current 12.5 A (max load at 100 VAC)
10.5 A (max load at 120 VAC)
6.0 A (max load at 200 VAC)
19.5 A (max load at 100 VAC)
16.0 A (max load at 120 VAC)
10.0 A (max load at 200 VAC)
AC Inrush Current 16 A peak, one cycle 48.65 A peak @ 140 VAC/60Hz
AC Input Power 1250 VA maximum 1700 VA maximum
Power Supply Output Rating 925 watts DC continuous 1200 watts DC continuous
Holdup without system reset 25ms at 50/60Hz (1 cycle, or 500ms) 20ms at 50/60Hz (1 cycle, or 500ms)
Battery Backup Time 15 minutes
With optional external PowerTrust UPS.
Without the optional UPS there is no
battery backup.
15 minutes
With optional external PowerTrust UPS.
Without the optional UPS there is no
battery backup.

Table of Contents