B-7
Table B-12. Electromagnetic and Electrostatic Specifications.
Description
Specification
HP 9000 - 
K100, K200, K400, K210,
K410, K220, & K420
HP 3000 - 939KS, 959KS, 929KS,
969KS/x00, & 969KS/x20
HP 9000 - K250, K260, K450, & K460
HP 3000 - 979KS
Radiated Field Immunity 3 Volts/Meter (27 MHz to 1 GHz) 3 Volts/Meter (27 MHz to 1 GHz)
Magnetic Field Immunity 1 Gauss (47.5 Hz to 198 Hz) 1 Gauss (47.5 Hz to 198 Hz)
Electrostatic Discharge 
Immunity
15 kV 
(Maximum, with no loss of function)
25 kV 
(Maximum, with no component damage)
15 kV 
(Maximum, with no loss of function)
25 kV 
(Maximum, with no component damage)
Electrostatic Contact Discharge 3 kV (No Effect) 3 kV (No Effect)