EasyManuals Logo

HP 5120 EI Series Installation Guide

HP 5120 EI Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
17
Installing a 5120 EI switch in a 19-inch rack
You can install a 5120 EI switch in a 19-inch standard rack by using different mounting positions. Table
6 shows the installation methods available for the switches of different depths.
Table 6 Installation methods
Chassis Depth
Use front
mounting
brackets
only
Use front mounting
brackets and a rack
shelf
Use front and
rear mounting
brackets
5120-24G EI (2 slots)
5120-24G EI TAA (2 slots)
5120-48G EI (2 slots)
5120-48G EI TAA (2 slots)
5120-24G EI
5120-48G EI
300 mm
(11.81 in)
Yes (see
Rack-mounti
ng by using
only front
mounting
brac
kets
Yes (see
Rack-mounting by
using front mounting
brackets and a rack
shelf”)
No
5120-24G-PoE+ EI (2 slots)
5120-24G-PoE+ EI TAA (2 slots)
5120-48G-PoE+ EI (2 slots)
5120-48G-PoE+ EI TAA (2 slots)
420 mm
(16.54 in)
No
Yes (see
Rack-mounting by
using front
mounting
brackets and a rack
shelf”)
Yes (see
Rack-mounting
by using front
and rear
mounting
brac
kets”)
NOTE:
For a switch with a 420 mm (16.54 in) of depth, the front mounting brackets are not weight-bearing.
Mounting brackets
Figure 30 Front mounting bracket
1
2
(1) Hole for attaching to a rack (by using an M6 screw)
(2) Hole for attaching to the switch chassis

Table of Contents

Other manuals for HP 5120 EI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5120 EI Series and is the answer not in the manual?

HP 5120 EI Series Specifications

General IconGeneral
BrandHP
Model5120 EI Series
CategorySwitch
LanguageEnglish

Related product manuals