27
Removing an HP 830 uplink module
1. Wear an ESD-preventive wrist strap, and make sure it makes good skin contact and is well
grounded.
2. Use a Phillips screwdriver to completely loosen the captive screws at both sides of the module.
3. Pull the module outward until it is completely out of the switch chassis.
Connecting the power cord
Connecting an AC power cord
1. Verify that the chassis ground is correctly connected to the earth ground.
2. Connect one end of the AC power cord to the AC-input power receptacle on the switch, and the
other end to the AC power source.
3. Use the cable tie supplied with the switch to secure the power cord to the chassis.
Figure 33 Connecting the AC power cord
(1) Rear panel (2) AC power cord
4. Examine the system LED (PWR) on the front panel of the switch. If the LED is on, the AC power input
is normal.
Connecting the switch to an RPS
CAUTION:
erify that the grounding cable is properly connected before powering on the switch.
The RPS power supply is optional. The switch supports RPS power supply model RPS 1600.
To connect the switch to an RPS:
1. Verify that the switch is powered off and the RPS is switched off.
2. Use a Phillips screwdriver to remove the screws on the cover of the DC power receptacle, and take
off the cover.
3. Connect the RPS power cord to the DC power receptacle on the chassis.
4. Turn the strain release screws on the RPS power cord clockwise so that the RPS power cord plug
is firmly seated in the DC power receptacle, and then fasten the strain release screws.