A-Class System Service
Replacing an A-Class Server Exchange Base Unit (EBU)
Chapter 3
101
The following configuration information can be obtained from the Web Console Main
Menu:
• IP Configuration:
— Secure Console Name
— IP Address
—IP Subnet Mask
—IP Gateway
— System Name.
• Datacomm Configuration:
—Baud Rate
— Parity/Data Bits
—Parity Checking
— Recvpace/Xmitpace.
When the new EBU has been received, place the original system and the new EBU
side-by-side on an ESD-protected work area. Now you can remove the FRUs from the
original system and install them directly into the new EBU.
CAUTION The procedures in this section require opening the system cabinet and exposing the
system to electrostatic discharge. Always observe all electrostatic precautions when
working with components inside or out of the cabinet. Failure to follow these precautions
may result in component damage or loss of system reliability.
Electrostatic Discharge Precautions
• Use a grounding mat and an anti-static wrist strap.
• Wear the anti-static wrist strap to ensure that any accumulated electrostatic charge
is discharged from your body to ground.
Before You Do Anything...
Step 1. Perform system backup.
Step 2. Shut down the operating system.
Step 3. Power down the system.
Step 4. Unplug the server.
NOTE Cabinet-mounted servers must be removed from the cabinet before proceeding.