A-Class System Service
A-Class Server Trouble Shooting
Chapter 3
75
INIT C4CC
INIT C4CD
INIT 3002
TEST 30BC
INIT 30BC
INIT C300
TEST 1030
<Press any key to continue (q to quit)> q
Service Menu: Enter command >
• OSTAT values of TEST and INIT are common during selftest.
• OSTAT values of RUN and SHUT are common when the HP-UX operating system is
running.
• OSTAT values FLT, OFF, and WARN are used to indicate when the server firmware
has failed a test or detected a problem that does not keep selftest from finishing.
If a fault prevents the server from completing selftest, the OSTAT FLT is used and the
Chassis Code displays the test number that failed. If the server stops responding while
performing a test, the OSTAT value will be INIT or TEST and the chassis code
represents the test that was running when the server failed.
Refer to the table below to determine which tests were active when the system either
faulted or stopped responding during selftest, and the corrective action to take in
response to the problem.
Major
Code
Category
Description Corrective Action
1xxx CPU/TLB Tests Refer to Replacing an A-Class Server Exchange
Base Unit (EBU)
2xxx SLC Tests Refer to Second Level Cache Memory Module
Fault.
3xxx PDH Tests Refer to Replacing an A-Class Server Exchange
Base Unit (EBU)
4xxx Late Selftest Refer to Replacing an A-Class Server Exchange
Base Unit (EBU)
5xxx Bus Transactions Refer to I/O Subsystem or I/O Board Fault
6xxx Unused NA
7xxx Memory Tests Refer to Second Level Cache/RAM Memory
Module Faults
8xxx I/O Device Codes Refer to I/O Subsystem or I/O Board Fault