4-23
Web and MAC Authentication
Configuring Web Authentication
Figure 4-6. Adding Web Servers with the aaa port-access web-based ews-server Command
Syntax: aaa port-access web-based [dhcp-addr <ip-address/mask>]
Specifies the base address/mask for the temporary IP
pool used by DHCP. The base address can be any valid
ip address (not a multicast address). Valid mask range
value is <255.255.240.0 - 255.255.255.0>.
(Default: 192.168.0.0/255.255.255.0)
Syntax: aaa port-access web-based [dhcp-lease <5 - 25>]
Specifies the lease length, in seconds, of the temporary
IP address issued for Web Auth login purposes.
(Default: 10 seconds)
Syntax: aaa port-access web-based [ewa-server <ipv4-addr | hostname>
[<page-path>]]
Configures a connection with the web server at the
specified IPv4 address (ipv4-addr) or host name (ipv4-
addr) on which customized login web pages used for
Web Authentication are stored. A maximum of 3 web
servers may be configured on the switch.
The optional <page-path> parameter defines the direc-
tory path on the server where all customized login web
pages (graphics, HTML frames, and HTML files) are
stored. (Default: The default <page-path> value is/” for
root directory. If the web server is also used for other
purposes, you may wish to group the HTML files in
their own directory, for example in “/EWA/”)
HP Switch (config)# aaa port-access web-based 47 ewa-server 10.0.12.179
/EWA
HP Switch (config)# aaa port-access web-based 47 ewa-server 10.0.12.180
/EWA
HP Switch (config)#

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP E3800 Series and is the answer not in the manual?

HP E3800 Series Specifications

General IconGeneral
ModelHP E3800 Series
LayerLayer 3
Uplink Ports4 x SFP+ ports
StackingYes
Power over Ethernet (PoE)Available on some models
ManagementWeb, CLI, SNMP
Power SupplyRedundant (optional)
Operating Temperature0°C to 45°C
Dimensions (W x D x H)440 x 424 x 44 mm
Operating Humidity10% to 90% non-condensing

Related product manuals