13-35
Configuring Port-Based and User-Based Access Control (802.1X)
802.1X Open VLAN Mode
Table 13-1. 802.1X Open VLAN Mode Options
802.1X Per-Port Configuration Port Response
No Open VLAN mode: The port automatically blocks a client that cannot initiate an
authentication session.
Open VLAN mode with both of the following configured:
Unauthorized-Client VLAN When the port detects a client without 802.1X supplicant
capability, it automatically becomes an untagged member of this
VLAN. If you previously configured the port as a static, tagged
member of the VLAN, membership temporarily changes to
untagged while the client remains unauthenticated.
If the port already has a statically configured, untagged
membership in another VLAN, then the port temporarily closes
access to this other VLAN while in the Unauthorized-Client VLAN.
To limit security risks, the network services and access available
on the Unauthorized-Client VLAN should include only what a client
needs to enable an authentication session. If the port is statically
configured as a tagged member of any other VLANs, access to
these VLANs is blocked while the port is a member of the
Unauthorized-Client VLAN.
Note for a Port Configured To Allow Multiple Client Sessions: If any
previously authenticated clients are using a port assigned to a VLAN
other than the Unauthorized-Client VLAN, then a later client that is
not running 802.1X supplicant software is blocked on the port until all
other, authenticated clients on the port have disconnected.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP E3800 Series and is the answer not in the manual?

HP E3800 Series Specifications

General IconGeneral
ModelHP E3800 Series
LayerLayer 3
Uplink Ports4 x SFP+ ports
StackingYes
Power over Ethernet (PoE)Available on some models
ManagementWeb, CLI, SNMP
Power SupplyRedundant (optional)
Operating Temperature0°C to 45°C
Dimensions (W x D x H)440 x 424 x 44 mm
Operating Humidity10% to 90% non-condensing

Related product manuals