16-7
Key Management System
Configuring Key Chain Management
Figure 16-4. Display of Time-Dependent Keys in the Key Chain Entry
You can use show key-chain to display the key status at the time the command
is issued. Using the information from the example configuration in figures
16-3 and 16-4, if you execute show key-chain at 8:05 on 01/19/03, the display
would appear as follows:
Figure 16-5. Status of Keys in Key Chain Entry “HP Switch2”
HP Switch(config)# key-chain HP Switch2
Chain - HP Switch2
|
Key | Accept Start GMT Accept Stop GMT Send Start GMT Send Stop GMT
---- + ----------------- ----------------- -------------- ----------------
1 | 01/17/03 08:00:00 01/18/03 08:10:00 01/17/03 08:00:00 01/18/03 08:00:00
2 | 01/18/03 08:00:00 01/19/03 08:10:00 01/18/03 08:00:00 01/19/03 08:00:00
3 | 01/19/03 08:00:00 01/20/03 08:10:00 01/19/03 08:00:00 01/20/03 08:00:00
4 | 01/20/03 08:00:00 01/21/03 08:10:00 01/20/03 08:00:00 01/21/03 08:00:00
5 | 01/21/03 08:00:00 01/22/03 08:10:00 01/21/03 08:00:00 01/22/03 08:00:00
OSPF interface References
Interface
---------------------
OSPF Virtual Link References
Area/Virtual Link
------------------------------
HP Switch(config)# show key-chain
Key Chains
Chain Name Keys Active Expired
------------------- ------ ------- -------
HP Switch1 1 1 0
HP Switch2 5 2 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP E3800 Series and is the answer not in the manual?

HP E3800 Series Specifications

General IconGeneral
ModelHP E3800 Series
LayerLayer 3
Uplink Ports4 x SFP+ ports
StackingYes
Power over Ethernet (PoE)Available on some models
ManagementWeb, CLI, SNMP
Power SupplyRedundant (optional)
Operating Temperature0°C to 45°C
Dimensions (W x D x H)440 x 424 x 44 mm
Operating Humidity10% to 90% non-condensing

Related product manuals