5-104 Chapter5
Language Reference
SOURce Subsystem
Set the Output Power Step Size
:SOURce:POWer:STEP[:INCRement] <ampl>
:SOURce:POWer:STEP[:INCRement]?
Specifies the source power step size.
Default Unit: dBm
Front Panel
Access: Source, Amptd Step Auto Man
Set the Source Sweep Power Range
:SOURce:POWer:SWEep <rel_ampl>
:SOURce:POWer:SWEep?
Specifies the range of power levels through which the source output will
sweep. Use :SOURce:POWer:STARt to set the power level at the start
of the power sweep. See also :SOURce:POWer:SPAN.
Factory Preset
and *RST: 0 dBm
Range: HP ESA E4401B, E4411B: –70 dBm to 3 dBm
HP ESA E4402B, E4403B: –66 dBm to 3 dBm
HP ESA E4404B: –66 dBm to 3 dBm
HP ESA E4405B: –66 dBm to 3 dBm
HP ESA E4407B, E4408B: –66 dBm to 3 dBm
Default Unit: dBm
Front Panel
Access: Source, Power Sweep On Off
Output Power Tracking
:SOURce:POWer:TRCKing <number>
:SOURce:POWer:TRCKing?
Adjusts the tracking of the source output with the spectrum analyzer
sweep in the present resolution bandwidth.
Factory Preset
and *RST: 2048
Range: Real, 0 to 4095
Remarks: This command is not applicable for the 1.5 GHz
tracking generator.