Error messages 113
Drive Offline due to Erase Operation: The physical drive is offline and the erase
process has completed...
...The drive may now be brought online through the re-enable erased drive command in ACU.
Action: Re-enable the physical drive using the Array Configuration Utility (on page 70).
Drive Offline due to Erase Operation: The physical drive is offline from having an
erase in progress.
Action: No action is required. The logical drive containing this physical drive cannot be migrated or
extended while the erase operation is in progress.
Logical drive state: A logical drive is configured with a newer version of
Storage/Config Mod than is currently running.
Action: Obtain the latest version of ACU.
Logical drive state: Background parity initialization is currently queued...
...or in progress on this logical drive. If background parity initialization is queued, it will start when I/O is
performed on the drive. When background parity initialization completes, the performance of the logical drive will
improve.
Action: No action is required.
Logical drive state: The current array controller is performing capacity
expansion,...
...extension, or migration on this logical drive.
Action: No action is required. Further configuration is disabled until the process completes.
Logical drive state: The logical drive is disabled from a SCSI ID conflict.
Action: Check all SCSI components to make sure they all have a unique SCSI ID.
Logical drive state: The logical drive is not configured.
Action: Refresh the system using the Array Configuration Utility (on page 70).
Logical drive state: The logical drive is not yet available.
Action: No action is required. This logical drive will remain in this state until all expand/shrink or move
operations on this array are completed. All I/O requests sent to the logical drive in this state will be
rejected.
Logical drive state: The logical drive is offline from being ejected.
Action: Reinstall the removed physical drives.