Component identification 90
Systems Insight Display
LED and color
Health LED color Status
DIMM (amber)
Red
DIMM in slot X has failed.
Amber DIMM in slot X is in a pre-failure condition.
DIMM (amber)
Red One or more DIMMs have failed. Test each bank of DIMMs
by removing all other DIMMs. Isolate the failed DIMM by
replacing each DIMM in a bank with a known working
DIMM.
Overtemperature (amber)
Amber The Health Driver has detected a cautionary temperature
level.
Red The server has detected a hardware critical temperature
level.
Fan (amber)
Amber One fan is failed or removed.
Red Two or more fans have failed or are missing.
Power supply (amber)
Red Only one power supply is installed and is in standby.
Power supply fault
System board fault
Power supply (amber)
Amber Redundant power supply is installed and only one power
supply is functional.
AC power cord not plugged into redundant power
supply
Redundant power supply fault
Power supply (amber)
Amber Power supply mismatch at POST or power supply mismatch
through hot add