System Inlet Temperature, Extended Ambient Operating Support
Specification Value
System Inlet Temperature, Extended Ambient Operating
Support
—
— For approved hardware configurations, the supported system
inlet range is extended to be 5°C to 10°C (41°F to 50°F) and
35°C to 40°C (95°F to 104°F)
All temperature ratings shown are for sea level with an
altitude derating of 10 °C per every 175 m (18°F per every
574 ft) above 900 m (2953 ft) to a maximum of 3050 m
(10000 ft).
1
— For approved hardware configurations, the supported system
inlet range is extended to be 40°C to 45°C (104°F to 113°F)
All temperature ratings shown are for sea level with an
altitude derating of 10 °C per every 125 m (18°F per every
410 ft) above 900 m (2953 ft) to a maximum of 3050 m
(10000 ft).
1
1
System performance may be reduced if operating in the extended ambient operating range or with a fan fault.
The approved hardware configurations for this system are listed on the
Hewlett Packard Enterprise website.
Mechanical specifications
Specification
Value
Height 1748 cm (688 in)
Depth 7518 cm (2960 in)
Width 4455 cm (1754 in)
Weight (maximum) 5171 kg (114 lbs)
Weight (minimum) 2812 kg (62 lbs)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
• HPE 800W Flex Slot Platinum Hot-plug Low Halogen Power Supply
• HPE 800W Flex Slot -48VDC Hot-plug Low Halogen Power Supply
• HPE 1600W Flex Slot Platinum Hot-plug Low Halogen Power Supply
For detailed power supply specifications, see the QuickSpecs on the Hewlett Packard Enterprise website (
http://
www.hpe.com/info/proliant/powersupply).
162