CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server
in this manner results in improper airflow and improper cooling that can lead to thermal damage.
5. If installed, remove the butterfly riser cage (Removing a butterfly PCIe riser cage).
6. Remove the primary PCIe riser cage (
Removing a primary PCIe riser cage).
7. Remove the air bale (Removing the air bale).
8. If installed, do one of the following:
Remove the processor mezzanine tray (Removing and replacing the processor mezzanine tray).
Remove the CPU Mezzanine UPI performance kit (Removing and replacing a CPU Mezzanine UPI performance kit
board).
9. Remove the fan cage (Removing and replacing the fan cage).
10. To remove or reroute cables, remove the fan cage holders (
Removing and replacing the fan cage holders).
11. Disconnect the cables from the drive cage backplane.
12.
Remove the hard drives (Removing and replacing an NVMe drive).
13.
Remove the drive cage.
To replace the component, reverse the removal procedure.
Removing and replacing a six-bay SFF HDD/two-bay NVMe SSD
(Premium) cage
Procedure
1.
Power down the server.
2. Remove all power:
Removal and replacement procedures
63