Four power supply configuration—For redundancy, connect power supplies 1 and 2 to power circuit A, and then
connect power supplies 3 and 4 to power circuit B.
25.
Power up the server.
26. Ensure all firmware, including option cards and embedded devices, is updated to the same versions to ensure that the
latest drivers are being used.
27. Re-enter any Secure Boot Keys that were previously added in the Secure Boot configuration.
28. Re-enter the server serial number and the product ID (Re-entering the server serial number and product ID).
29. Set the server power supply requirements (
Setting the server power supply requirements).
30. Review the persistent memory configuration of the server.
For more information, see Configuring the server for HPE Persistent Memory.
31. Do one of the following:
96