Server component identification 107
LED Description
SCSI BP The SCSI backplane is missing or not properly installed.
MEM A memory board is not properly installed.
MEM BP A memory backplane is missing or not properly installed.
FSB One or more of the following conditions exist:
• A processor or PPM is missing or not properly installed.
• An FSB configuration error was detected.
PROC A processor is missing or not properly installed.
OVER TEMP The internal temperature has exceeded operating levels.
NO BOOT A "no boot" condition was detected.
P84 Switch set to display port 84 codes.
P85 Switch set to display port 85 codes ("Troubleshooting the system using port 85 codes"
on page 84
).
Setting the switch to view port 85 codes
To change the display on the QuickFind diagnostic panel to view port 84 and 85
codes ("Troubleshooting the system using port 85 codes" on page 84
):
1. Extend the server from the rack.
2. Remove the access panel ("Removing the access panel" on page 19
).
3. Locate the switch on the media board.
4. Set the switch to the P85 position to view port 85 codes.