Server component identification 97
If the mode selected is the desired mode, modify the DIMM or board
configuration to support the desired mode. For more information, refer to
"Memory Options."
If the mode selected is not the desired mode, run RBSU and change the AMP
mode. For more information, refer to the section "HP ROM-Based Setup
Utility (on page 80
)."
NOTE: If the Spare, Mirrored, and RAID LEDs are off, the server is
in Advanced ECC mode. Refer to "HP ROM-Based Setup Utility (on
page 80
)" for more information.
Processor module LEDs
PPM LED (1) Processor LED
(2)
External health
LED
Description
Off Off Off One of the following conditions exist:
No AC power present
Normal
Off Amber Flashing amber Pre-failure error threshold exceeded; LEDs will
clear after the next reboot