Removal and replacement procedures 59
1. Remove the power supply blank.
To replace the component, reverse the removal procedure.
Removing a redundant hot-plug power supply
WARNING: To reduce the risk of electric shock, do not
disassemble the power supply or attempt to repair it. Replace it
only with the specified spare part.
CAUTION: If only one power supply is installed, do not remove the
power supply unless the server has been powered down. Removing the
only operational power supply will cause an immediate power loss.
NOTE: If you remove or replace the primary hot-plug power
supply, use the T-15 Torx screwdriver provided with the server to
remove the shipping screw. It is located just under the port-colored
plastic handle of the power supply unit.
NOTE: Refer to the section "Power supply LEDs (on page 100)"
for information on the current status of the hot-plug power supply.
1. Disconnect the power cord from the power supply.
2. Remove the shipping screw, if applicable.