34 HP ProLiant DL580 Generation 3 Server Maintenance and Service Guide
7. Remove the expansion board.
To replace the component, reverse the removal procedure.
Removing the PCI-X Hot Plug mezzanine option
1. Power down the server ("Powering down the server" on page 18).
2. Extend or remove the server from the rack ("Removing the server from the
rack" on page 19
).
3. Remove the access panel ("Removing the access panel" on page 19
).
4. Remove the expansion boards from slots 1 and 2.
5. Remove the expansion boards from slots 3 and 4, if installed, to gain access
to the mezzanine board.
6. Remove the PCI-X Hot Plug basket ("Removing the PCI-X Hot Plug basket"
on page 32
).
7. Disconnect the cable from the PCI-X Hot Plug mezzanine board.