1 HDD PWR (PDB) Connects to RPS power distribution board
2 ODD PWR Connects to the optical drive
3 P4 Connects to the LTO/RDX power extension cable
4 LTO PWR LTO/RDX power connector
5 P2 Connects to the LTO/RDX power extension cable
6 NHP PWR Connects to the SATA-power splitter cable in the 4
LFF non-hot-plug drive configuration
7 BP HP PWR Connects to the 4 LFF / 8 SFF hot-plug drive
backplane
ItemItem Cable labelCable label ConnectionConnection
SpecificationsSpecifications
This chapter lists the technical specifications for the server, including:
Environmental specifications
Mechanical specifications
Power supply specifications
Environmental specificationsEnvironmental specifications
SpecificationsSpecifications ValueValue
Temperature range*Temperature range* —
Operating 10°C to 35°C (50°F to 95°F)
Nonoperating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)Relative humidity (noncondensing) —
Operating 8% to 90%
28°C (82.4°F) maximum wet bulb temperature, noncondensing
Nonoperating 5% to 95%
38.7°C (101.7°F) maximum wet bulb temperature, noncondensing
AltitudeAltitude —
Operating 3050 m (10,000 ft)
This value may be limited by the type and number of options installed.
Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).
Nonoperating 9144 m (30,000 ft)
Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).