ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
If the server is in rack mode, remove the server from the rack .
5. Remove the front bezel.
6. Remove the access panel.
7. Disconnect the drive cable from the media drive specified in the procedure:
LTO tape drive SAS-power Y-cable
RDX drive power and USB cables
Optical drive SATA-power Y-cable
8. Pull and hold the drive release latch (callout 1), and then slide the media drive out of the bay (callout 2).
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide 39