EasyManua.ls Logo

HP ProLiant ML30 Gen10 Plus - Page 57

HP ProLiant ML30 Gen10 Plus
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
CAUTION: CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated
with either a component or a blank.
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
If the server is in rack mode, remove the server from the rack .
5. Remove the front bezel.
6. Remove the access panel.
7. Disconnect the drive power and SAS cables .
8. Pull up and hold the release latch (callout 1), and then remove the LTO tape drive (callout 2).
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide 57