HPEHPE Basic Drive LED definitions Basic Drive LED definitions
LFF LFF low-profile drive carrierlow-profile drive carrier
The LFF low-profile drive carrier supports hot-plug SAS and SATA drives .
SFF SFF basic drive carrierbasic drive carrier
The SFF basic drive carrier supports hot-plug SAS and SATA drives .
ItemItem LEDLED StatusStatus DefinitionDefinition
1 Fault/Locate Solid amber This drive has failed, is unsupported, or is invalid.
Solid blue The drive is operating normally and being identified by a
management application.
Flashing amber/blue The drive has failed, or a predictive failure alert has been received
for this drive. The drive has also been identified by a management
application.
Flashing amber A predictive failure alert has been received for this drive. Replace
the drive as soon as possible.
2 Online/Activity Solid green The drive is online and has no activity.
Flashing green (1 flash
per second)
The drive is doing one of the following:
Rebuilding or performing a RAID
Performing a stripe size migration
Performing a capacity expansion
Performing a logical drive extension
Erasing
Spare part activation
Flashing green (4
flashes per second)
The drive is operation normally and has activity.