Hardware options installation 57
15.
Do one of the following:
Close or install the tower bezel, as needed.
Slide the server back into the rack.
16. Power up the server (on page 20).
Redundant hot-plug fans option
The server supports redundant hot-plug fans to provide proper airflow to the system if a primary fan fails.
In the standard configuration, fans 1, 2 and 3 cool the server.
For the redundant configuration, fans 4, 5 and 6 are added to back up the primary fans. This
configuration allows the server to continue operation in non-redundant mode, if a fan failure occurs.
WARNING: To prevent personal injury from hazardous energy:
Remove watches, rings, or other metal objects.
Use tools with insulated handles.
Do not place tools or metal parts on top of batteries.
To install the fans:
1. Do one of the following:
Open or remove the tower bezel, as needed ("Open or remove the tower bezel" on page 21).
Extend the server from the rack (on page 22).
2. Remove the access panel. ("Remove the access panel" on page 25)
3. Install three hot-plug fans into the center wall.
4. Install the access panel.
5. Do one of the following:
Close or install the tower bezel, as needed.
Slide the server back into the rack.