EasyManua.ls Logo

HP StorageWorks MSA1000

HP StorageWorks MSA1000
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 23
Example show this_controller command and response
CLI> show this_controller
Controller 1 (right controller):
MSA1500 c Hewlett-Packard xxx Version 6.86 Build 122 Hardware 7
Component Enclosure.
Controller Identifier:
NODE_ID=yyyyyyyy-yyyyyyyy
SCSI_VERSION=SCSI-3
Supported Redundancy Mode: Active/Standby Asm-Active/Active
Current Redundancy Mode: Asym-Active/Active
Device Port SCSI address 6
Terminal speed for the CLI is set to 19200.
Host Port_1:
REPORTED PORT_ID YYYYYYYYY-YYYYYYYYY
PORT_1_TOPOLOGY=F_Port
Cache:
128 megabytes read cache 128 megabytes write cache Version 2
Cache is GOOD, and Cache is enabled
No unflushed data in cache
Battery:
Module #1 is fully charged and turned off.
Controller Up Time:
5 Days 06 Hours 01 Minutes 51 Seconds
Health:
Surface Scan: Complete.
Rebuild Status: Complete.
Expansion: Complete.

Table of Contents

Other manuals for HP StorageWorks MSA1000

Related product manuals