HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 35
Global commands
The CLI provides the ability to configure the MSA controller, enter global settings, and perform system-wide
commands, including:
Setting global variables
Setting the controller ID
Setting hard addressing
Changing the CLI prompt
Updating MSA firmware
Disabling a controller for removal
Overriding the ACU lock
Enabling or disabling debug console logging
Setting global variables
A single command with a variety of parameters is used to set the expand priority, the read/write ratio, and
the system name.
Basic command
set globals [expand_priority=p] [rebuild_priority=r] [system_name=”name”]
[read_cache=r] [write_cache=w]
Command options
expand_priority=p—the expand priority, where p represents the priority setting of low, medium, or
high. Used when expanding an array to set the priority of array expansions in relation to input/output
operations. See below for detailed information about these settings.
rebuild_priority=p—the rebuild priority, where p represents the priority setting of low, medium,
or high. Used when rebuilding an array to set the priority of an array rebuild in relation to input/output
operations. See below for detailed information about these settings.
lowexpansion or rebuild takes place only when the array controller is not busy handling normal
I/O requests. This setting has minimal effect on normal I/O operations. However, there is an
increased risk that data will be lost if another physical drive fails while the rebuild is in progress.
mediumexpansion or rebuild occurs for half of the time, and normal I/O requests are handled
during the rest of the time.
Highrebuild or expansion occurs at the expense of normal I/O operations. Although system
performance is affected, this setting provides better data protection because the array is vulnerable
to additional drive failures for a shorter time.
system_name=”name”—the system name, where “name” represents any user defined phrase, up to
20 alphanumeric characters. Quotation marks are required around the name.
read_cache=r—the read cache, where r specifies the read cache as a percentage of the total cache.
write_cache=w—the write cache, where r specifies the write cache as a percentage of the total
cache.
NOTE: The sum of read_cache and write_cache must equal 100.

Table of Contents

Other manuals for HP StorageWorks MSA1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks MSA1000 and is the answer not in the manual?

HP StorageWorks MSA1000 Specifications

General IconGeneral
RAID levels0, 1, 0+1, 5
CertificationMicrosoft Cluster Server Certification\\r Hewlett Packard Data Protector\\r VERITAS Backup Exec and NetBackup\\r Legato NetWorker for Windows\\r Computer Associates BrightStor Enterprise Backup
Internal memory256 MB
Memory clock speed- MHz
Internal memory type-
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)10 - 90 %
Supported storage drive interfacesSCSI
Windows operating systems supportedYes
Harmonized System (HS) code84733080
Weight and Dimensions IconWeight and Dimensions
Depth52.1 mm
Width48.3 mm
Height17.5 mm
Weight31210 g

Related product manuals