EasyManuals Logo

HP StorageWorks MSA1000 Software Guide

HP StorageWorks MSA1000
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide 29
Adding a spare to an existing LUN
Basic command
add spare unit=<#> <diskrange>
Command options
#—the unit to assign the spare to. This is the same number that was given to the unit when it was
created with the add unit command.
diskrange—indicates the drives to assign as the spare to the LUN. Disks are identified by box
number and bay number.
Example command and response
CLI> add spare unit=2 disk112
Available write cache lines: 0x37FD (592458:592420)
Available read cache lines: 0x37EE
Using write cache lines 0x0 to 0x1BFD
Hiding write cache lines 0x1BFE to 0x37FC
Using read cache lines 0x37FD to 0x53F3
Hiding read cache lines 0x53F4 to 0x6FEA
Spare drive(s) has been added. Use 'show unit 0' to confirm.
Deleting LUNs
NOTE: A LUN cannot be deleted if there are other LUNs after it. For example, if LUNs 0-3 are configured,
LUN 1 cannot be deleted without also deleting LUNs 2 and 3.
After a LUN is deleted, its unit number goes unused until manually assigned to a new LUN. Unit numbers
are not automatically reassigned when a LUN is deleted.
Basic command
delete unit <#> [-y]
Command options
#—the unit or range of units to delete. This is the same number that was given to the unit when it was
created with the add unit command.
-y—(optional) no user confirmation is required before the deletion is made.
Example command and response
CLI> delete unit 4
Data will be lost after the unit is deleted.
Do you still want to DELETE unit 4 (Y/N)? Y
Please wait while unit 4 is being deleted…
Unit 4 is deleted successfully.

Table of Contents

Other manuals for HP StorageWorks MSA1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks MSA1000 and is the answer not in the manual?

HP StorageWorks MSA1000 Specifications

General IconGeneral
RAID levels0, 1, 0+1, 5
CertificationMicrosoft Cluster Server Certification\\r Hewlett Packard Data Protector\\r VERITAS Backup Exec and NetBackup\\r Legato NetWorker for Windows\\r Computer Associates BrightStor Enterprise Backup
Internal memory256 MB
Memory clock speed- MHz
Internal memory type-
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)10 - 90 %
Supported storage drive interfacesSCSI
Windows operating systems supportedYes
Harmonized System (HS) code84733080
Weight and Dimensions IconWeight and Dimensions
Depth52.1 mm
Width48.3 mm
Height17.5 mm
Weight31210 g