EasyManua.ls Logo

HPE Cloudline CL2200 Gen10

HPE Cloudline CL2200 Gen10
157 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal and replacement procedures 99
Fan cage (SFF)
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
1. Power down the server (on page 20).
2. Disconnect all peripheral cables from the server.
3. Remove the access panel (on page 21).
4. Remove the fan duct (on page 69).
5. Untie and disconnect all relevant cables located on the left and right side of the system chassis, and
then remove them from their respective cable routing channels.
6. Disconnect all fan cables from the front drive cage backplane (on page 135).
7. Remove the fan cage bracket.
c. Remove the 2 screws securing the fan cage bracket to the system.
d. Lift and remove the fan cage bracket.

Table of Contents