Specifications
Environmental specifications
Specification Value
Temperature range
1
—
Operating 10°C to 35°C (50°F to 95°F)
Nonoperating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
—
Operating
Minimum to be the higher (more moisture) of -12°C
(104°F) dew point or 8% relative humidity
Maximum to be 24°C (752°F) dew point or 90% relative
humidity
Nonoperating
5% to 95%
387°C (1017°F), maximum wet bulb temperature
1
All temperature ratings shown are for sea level. An altitude derating of
10°C per 3048 m (18°F per 1000 ft) to 3048 m (10000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
• 5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 10°C per every
175 m (18°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m (10000 ft).
• 40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 10°C per every 125 m (18°F per every 410
ft) above 900 m (2953 ft) to a maximum of 3048 m (10000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise website.
Mechanical specifications
Dimension
Value
Height* 875 cm (344 in)
Depth* 6347 cm (2499 in)
Width* 4454 cm (1754 in)
Weight (approximate range)
13 kg to 26 kg (28 lb to 58 lb)
* These dimensions apply to all server models.
Specifications