HPEHPE Smart Storage Battery Smart Storage Battery
The HPE Smart Storage Battery supports both HPE SR and MR storage controllers.
A single 96 W battery can support up to 24 devices.
After the battery is installed, it might take up to two hours to charge. Controller features requiring backup power are not re-enabled until
the battery is capable of supporting the backup power.
This server supports the 96 W HPE Smart Storage Battery with the 145 mm cable.
HPEHPE Smart Storage Hybrid Capacitor Smart Storage Hybrid Capacitor
The HPE Smart Storage Hybrid Capacitor supports both HPE SR and MR storage controllers.
The capacitor pack can support up to two devices.
This server supports the HPE Smart Storage Hybrid Capacitor with the 145 mm cable.
Before installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum firmware requirements to
support the capacitor pack.
IMPORTANT:IMPORTANT:
If the system BIOS or controller firmware is older than the minimum recommended firmware versions, the capacitor pack
will only support one device.
The capacitor pack is fully charged after the system boots.
Installing an energy pack in configurations without the M.2 SSD pass-through cardInstalling an energy pack in configurations without the M.2 SSD pass-through card
PrerequisitesPrerequisites
Make sure that you have the storage controller backup power cable that ships with the storage controller.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.