EasyManua.ls Logo

HPE ProLiant DL365 Gen11 - Procedure; Install the access panel; Prerequisites

HPE ProLiant DL365 Gen11
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WARNING:WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to
cool before touching them.
CAUTION:CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in this
manner results in improper airflow and improper cooling that can lead to thermal damage.
ProcedureProcedure
1. Power down the server.
2. Extend the server from the rack .
3. Open or unlock the locking latch, slide the access panel to the rear of the chassis, and remove the access panel.
Install the access panelInstall the access panel
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
ProcedureProcedure
1. With the access panel latch open, insert the guide pin on the chassis through the hole on the bottom side of the latch.
2. Close the access panel latch.
The access panel slides to the closed position.
3. Lock the access panel latch.
HPE ProLiant DL365 Gen11 Server Maintenance and Service Guide 35

Table of Contents

Related product manuals