ProcedureProcedure
1. Extend the server from the rack .
2. Remove the access panel.
3. Remove the fan blank.
ResultsResults
To replace the component, reverse the removal procedure.
Removing and replacing a fanRemoving and replacing a fan
About this taskAbout this task
CAUTION:CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in this
manner results in improper airflow and improper cooling that can lead to thermal damage.
IMPORTANT:IMPORTANT: For optimum cooling, install fans in all primary fan locations.
ProcedureProcedure
1. Extend the server from the rack.
2. Remove the access panel.
3. Remove the fan.
IMPORTANT:IMPORTANT: When a hot-plug fan is removed, the other fans in the server will increase speed to compensate.
CAUTION:CAUTION: To avoid server shutdown, a fan must be replaced within 60 seconds of being removed.
HPE ProLiant DL365 Gen11 Server Maintenance and Service Guide 49