ItemItem LEDLED StatusStatus DefinitionDefinition
1 Fault/Locate Solid amber Drive has failed, unsupported, or invalid.
Solid blue Drive is operating normally and being identified by a management
application.
Flashing amber/blue (1
flash per second)
Drive has failed, or a predictive failure alert is received for the drive. The
drive has also been identified by a management application.
Flashing amber (1 flash per
second)
Drive predictive failure alert is received. Replace the drive as soon as
possible.
Off Drive is operating normally and is not identified by a management
application.
2 Online/Activity Solid green Drive is online and has no activity.
Flashing green (1 flash per
second)
Drive is doing one of the following:
Rebuilding or performing a RAID
Erasing
Flashing green (4 flashes
per second)
Drive is operating normally and has activity.
Off Drive is not configured by a RAID controller or is a spare drive.