a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
4. Remove the access panel.
5. Do one of the following:
Remove the air baffle.
If installed, remove the 4LFF midplane drive cage.
6. Do one of the following:
For Type-a Smart Array controllers, install the controller into the Smart Array connector.
For Type-p Smart Array controllers, install the controller into an expansion slot.
7. Cable the controller.
The installation is complete.
Installing an HPE Smart Array P824i-p MR Gen10 controller in a configured
server
Procedure
1. Back up data on the system.
2. Close all applications.
3. Update the server firmware if it is not the latest revision.