Removal and replacement procedures 38
7.
Remove the 92 × 32 mm system fan module.
To replace the component, reverse the removal procedure.
Upgrade fan module (92 x 38 mm)
To remove the component:
1. Power down the server (on page 24).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Place the server on its side.
4. Remove the access panel (on page 24).
5. If installed, remove the PCI air baffle (on page 25).
6. Remove the system air baffle (on page 26).
7. Press the middle of fan guard on rear panel.