Component identification 77
Rear panel LEDs
Item Description Status
1
Power supply LED
Solid green = Normal
Off = One or more of the following conditions exists:
Power is unavailable
Power supply failed
Power supply is in standby mode
Power supply error
2
iLO link LED
Green = Linked to network
Off = No network connection
3
iLO activity LED
Green or flashing green = Network activity
Off = No network activity
4
NIC activity LED
Green or flashing green = Network activity
Off = No network activity
5
NIC link LED
Green = Linked to network
Off = No network connection
6
UID button/LED
Solid blue = Activated
Flashing blue:
1 flash per second = Remote management or firmware upgrade
in progress
4 flashes per second = iLO manual reboot sequence initiated
8 flashes per second = iLO manual reboot sequence in progress
Off = Deactivated