Hardware options installation 104
8.
Install the DIMM.
For more information about LEDs and troubleshooting failed DIMMs, see "Systems Insight Display LED
combinations (on page 14)."
SFF media cage option
For more information about product features, specifications, options, configurations, and compatibility,
see the product QuickSpecs on the Hewlett Packard Enterprise website (http://www.hpe.com/info/qs).
To install the component:
1. Do one of the following:
o For tower models, open and remove the tower bezel ("Remove the tower bezel" on page 31).
o For rack models, if installed, remove the security bezel ("Remove the security bezel (optional)"
on page 31).
2. Power down the server (on page 30).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
o For tower models, place the server on a flat, level surface with the access panel facing up.
o For rack models, extend the server from the rack (on page 34).
5. Remove the access panel (on page 32).
6. Remove the air baffle (on page 34).
7. Remove the fan cage (on page 37).